{"id":231,"date":"2017-10-11T03:48:34","date_gmt":"2017-10-11T01:48:34","guid":{"rendered":"http:\/\/www.fremap.com\/?page_id=231"},"modified":"2018-07-25T13:19:44","modified_gmt":"2018-07-25T11:19:44","slug":"threaded-inline","status":"publish","type":"page","link":"http:\/\/www.fremap.com\/?page_id=231&lang=en","title":{"rendered":"Threaded Inline"},"content":{"rendered":"<h3>Description<\/h3>\n<p>Stainless Steel threaded heaters for heating high-pressure air or inert gases to 1400\u00b0F (760\u00b0C). Sizes from 3\/8\u201d<br \/>\nto 2-1\/2\u201d diameter, and in wattages from 1.6 to 18 Kilowatts. If operated correctly, the heater will operate<br \/>\ncontinuously for 5000 hours or longer.<br \/>\n<img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-456\" src=\"http:\/\/www.fremap.com\/wp-content\/uploads\/2017\/10\/Threaded_Inline-1.jpg\" alt=\"\" width=\"250\" height=\"188\" \/><\/p>\n<h4>Specifications<\/h4>\n<ul>\n<li>Air temperatures to 1400\u02daF (760\u02daC)<\/li>\n<li>For applications requiring high pressure air<\/li>\n<li>Both ends threaded 3\/8&Prime;, 1\/2&Prime;, 1-1\/4&Prime;, and 2-1\/2&Prime; NPT<\/li>\n<li>304 Stainless Steel housing<\/li>\n<\/ul>\n<p><strong>CE compliant<\/strong><\/p>\n<p>&nbsp;<\/p>\n<p class=\"ecxmsonormal\"><span lang=\"EN-US\"><strong>The Inline High Temperature 900\u00b0C:<\/strong><\/span><\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"alignnone wp-image-458\" src=\"http:\/\/www.fremap.com\/wp-content\/uploads\/2017\/10\/photo_Inline_900xC-1.jpg\" alt=\"\" width=\"372\" height=\"272\" srcset=\"http:\/\/www.fremap.com\/wp-content\/uploads\/2017\/10\/photo_Inline_900xC-1.jpg 494w, http:\/\/www.fremap.com\/wp-content\/uploads\/2017\/10\/photo_Inline_900xC-1-300x219.jpg 300w\" sizes=\"(max-width: 372px) 100vw, 372px\" \/><\/p>\n<h4>Installation<\/h4>\n<ul>\n<li>Securely mount the heater.<\/li>\n<\/ul>\n<h4>FOR 3\/8\u201d, \u00bd\u201d, AND 1 \u00bc\u201d HEATER ONLY (#038821, 038822, 038823, 038824, 038825, AND 038826):<\/h4>\n<ul>\n<li>There are two feedthroughs on the heater. Each feedthrough has three wires (marked 1, 2, or 3) coming out of it.<\/li>\n<li>Connect one power lead to one heater electrical feedthrough (or one lead wire) and connect the other power<br \/>\nlead to the other electrical feedthrough. (or other lead wire).<\/li>\n<li>Connect the ground wire to the green grounding nut on the heater body.<\/li>\n<li>Connect the air source to the heater.<\/li>\n<li>If a thermocouple is used, ensure that it is located within one inch from the heater exit.<\/li>\n<\/ul>\n<h4>FOR 2 \u00bd\u201d HEATER ONLY (#063007):<br \/>\n18,000 WATT &#8211; 240 VOLT &#8211; SINGLE PHASE OPERATION:<\/h4>\n<ul>\n<li>Each of the two heater feedthroughs has three wires (marked 1, 2, or 3) coming out of it.<\/li>\n<li>Connect one side of power to all three leads that exit one feedthrough (1, 2, and 3 together).<\/li>\n<li>Connect the other side of the power to all three leads that exit the second feedthrough (1, 2, and 3 together).<\/li>\n<li>Make sure the heater is properly grounded. Note: Run single phase, 240 volts, the heater will draw 75 Amps.<\/li>\n<li>Connect the air source to the heater.<\/li>\n<li>If a thermocouple is used, ensure that it is located within one inch from the heater exit.<\/li>\n<\/ul>\n<h4>18,000 WATT &#8211; 240 VOLT &#8211; THREE PHASE OPERATION:<\/h4>\n<ul>\n<li>Each of the two heater feedthroughs have three wires (marked 1, 2, or 3) coming out of it.<\/li>\n<li>Connect the elements in a standard delta configuration. (Connect one power lead to each of the following pairs: 1-2, 2-3, 3-1).<\/li>\n<li>Make sure the heater is properly grounded.<\/li>\n<li>Note: Run three phase, 240 volts, the heater will draw 44 Amps.<\/li>\n<li>Connect the filtered air source to the heater.<\/li>\n<li>If a thermocouple is used, ensure that it is located within one inch from the heater exit.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><span lang=\"EN-US\">Datasheet :\u00a0<a href=\"http:\/\/www.tutcosureheat.com\/uploads\/3\/8\/7\/1\/38712199\/operating_manual_-_threaded_inline_-_zdf_2835460_rev_03.pdf\">Inline Manuel<\/a><\/span><\/p>\n<p class=\"ecxmsonormal\"><span lang=\"EN-US\">The Inline high temperature #076339 8 kW \/ 240V is able to heat 350Lpm of air at 900\u00b0C under pressure of 7 bars.<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Description Stainless Steel threaded heaters for heating high-pressure air or inert gases to 1400\u00b0F (760\u00b0C). Sizes from 3\/8\u201d to 2-1\/2\u201d diameter, and in wattages from 1.6 to 18 Kilowatts. If operated correctly, the heater will operate continuously for 5000 hours or longer. Specifications Air temperatures to 1400\u02daF (760\u02daC) For applications requiring high pressure air Both [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":207,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"http:\/\/www.fremap.com\/index.php?rest_route=\/wp\/v2\/pages\/231"}],"collection":[{"href":"http:\/\/www.fremap.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/www.fremap.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/www.fremap.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.fremap.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=231"}],"version-history":[{"count":8,"href":"http:\/\/www.fremap.com\/index.php?rest_route=\/wp\/v2\/pages\/231\/revisions"}],"predecessor-version":[{"id":645,"href":"http:\/\/www.fremap.com\/index.php?rest_route=\/wp\/v2\/pages\/231\/revisions\/645"}],"up":[{"embeddable":true,"href":"http:\/\/www.fremap.com\/index.php?rest_route=\/wp\/v2\/pages\/207"}],"wp:attachment":[{"href":"http:\/\/www.fremap.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=231"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}